ELB Electronics LED T8 U-Bend and 8’ direct replacement lamps, requiring NO Re-WIRING of the light fixture, provide excellent energy savings when replacing T8 and T12 fluorescent lamps. Installation is easy…just remove existing fluorescent lamps and install the LED linear lamp.
Multi-OpTM (multi-Operation) LED lamp design works with multiple input sources including T8 Electronic Instant Start, T8 Program Start and T12 Magnetic ballasts.
![]() |
|
|
The Multi-OpTM LED product is the most versatile LED linear lamp on the market today. The LED Multi-OpTM liner lamp is also compatible with most existing fluorescent emergency ballasts.
If the existing ballast fails just replace the ballast or operate the LED lamp with the optional 120-277VAC LED remote driver.
Benefits:
- Easy to carry, store and ships easily
- Excellent for low temperature applications
- Use with occupancy sensors with frequent starting
- Instant ON operation - No flickering
- Dimmable
- No glass or mercury for safer work environments
- Less lumen deprecation compared to fluorescent systems
- Meets UL standard 1598c
- Long life product (>55,000 hours)
- 5 Year manufacturer’s warranty
|
Energy Savings over 40-50% when compared to existing fluorescent T8 and T12 electronic and magnetic ballasted fixture applications. For additional energy savings of 20-30% use with low ballast factor ballast or lighting control system. Installation is easy and saves money. Just change the existing lamps without the need to re-wire the light fixture. Install LED lamp using existing fluorescent ballast. If the ballast fails, LED lamp can operate using optional 120-277VAC LED driver. LED direct replacement models available for 2’, 4’, U-Bend and 8’ fluorescent replacement. |
|
Pending completion |
|
INNOVATIVE two piece designs provide easy handling and transporting. Lamp snaps together in seconds. |
|
PRELIMINARY |
Specifications:
Performance with various ballast types:
|
Model # |
Type |
T8 IS Electronic ballast |
T8 Program Start Electronic ballast |
T12 Magnetic ballast |
|||
|
Lumens |
Average System Watts |
Lumens |
Average System Watts |
Lumens |
Average System Watts |
||
|
4’ U-Bend lamp |
|
|
|
|
|
|
|
|
LEDT8-17U-850-B-xxx |
LED T8 |
1650 |
16.45 |
1650 |
17.0 |
2100 |
28.0 |
|
LEDT8-17U-840-B-xxx |
LED T8 |
1600 |
16.45 |
1600 |
17.0 |
2000 |
28.0 |
|
LEDT8-17U-835-B-xxx |
LED T8 |
1500 |
16.45 |
1500 |
17.0 |
1950 |
28.0 |
|
LEDT8-17U-830-B-xxx |
LED T8 |
1500 |
16.45 |
1500 |
17.0 |
1900 |
28.0 |
|
8’ linear lamp |
|
|
|
|
|
|
|
|
LEDT8-44-850-B-xxx |
LED T8 |
3800 |
40.2 |
|
|
|
|
|
LEDT8-44-840-B-xxx |
LED T8 |
3700 |
40.2 |
|
|
|
|
|
LEDT8-44-835-B-xxx |
LED T8 |
3500 |
40.2 |
|
|
|
|
|
LEDT8-44-830-B-xxx |
LED T8 |
3500 |
40.2 |
|
|
|
|
Note: All specification Information subject to change without notice
U-Bend size extensions: (Order with tube sections)
|
LEDT8-U6 |
Extension to support 6” U-bend width |
|
LEDT8-U3 |
Extension to support 3” U-bend width |
|
LEDT8-U1-5/8 |
Extension to make 1-5/8” U-bend width |
|
LED T8 Performance with different ballast factor Instant Start (IS) ballasts |
T8 IS Low Ballast Factor (0.78) |
T8 IS Normal Ballast Factor (0.88) |
T8 IS High Ballast Factor (1.18) |
|||
|
|
Lumens |
Lamp Watts |
Lumens |
Lamp Watts |
Lumens |
Lamp Watts |
|
LEDT8-17U-850-B-xxx |
1450 |
14.50 |
1650 |
16.50 |
2100 |
22 |
|
LEDT8-17U-840-B-xxx |
1400 |
14.50 |
1600 |
16.50 |
2000 |
22 |
|
LEDT8-17U-835-B-xxx |
1300 |
14.50 |
1500 |
16.50 |
1900 |
22 |
|
LEDT8-17U-830-B-xxx |
1300 |
14.50 |
1500 |
16.50 |
1900 |
22 |
|
Step 1: Turn Power - OFF |
|
Step 2: Remove Fluorescent lamp |
|
Step 3: Plug in Quick-Fit LED lamp |
|
Step 4: Turn Power - ON |
|
Installation Instructions: Quick and Simple - No re-wiring required |
|
Program Start Electronic T8 or Magnetic T12 Rapid Start Ballast |
Existing Ballast Wiring Options:
|
Instant Start T8 Ballast |
|